Project

General

Profile

Actions

Bug #1886

closed

Config upgrade needs to move MTU values to MSS

Added by Chris Buechler over 12 years ago. Updated over 12 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
-
Category:
Configuration Upgrade
Target version:
Start date:
09/17/2011
Due date:
% Done:

100%

Estimated time:
Plus Target Version:
Release Notes:
Affected Version:
2.0
Affected Architecture:

Description

Config upgrade for 1.x to 2.x versions needs to move MTU values on interfaces to MSS. The MTU field in 2.0 does what it actually says, where in previous versions it actually just sets MSS clamping without changing the interface MTU. To retain the same configuration and behavior, during config upgrade the MTU settings must be changed to MSS.

Actions #1

Updated by Jim Pingle over 12 years ago

  • Status changed from New to Feedback
  • % Done changed from 0 to 100
Actions #2

Updated by Jim Pingle over 12 years ago

Actions #3

Updated by Chris Buechler over 12 years ago

  • Status changed from Feedback to Resolved
Actions