Project

General

Profile

Bug #4040

gateway monitoring issues with multiple PPPoE with same gateway

Added by Chris Buechler about 4 years ago. Updated about 4 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Ermal Luçi
Category:
Gateway monitoring
Target version:
Start date:
11/24/2014
Due date:
% Done:

100%

Estimated time:
Affected Version:
All
Affected Architecture:

Description

With multiple PPPoE connections with the same gateway, the static route for the monitor IP can end up on the wrong interface, which ends up marking the affected gateway as down.

potentially a secondary issue here in that the ICMP state for the monitor IP can cause breakage, such as if the route to a destination changes after the state exists.

Associated revisions

Revision 7a63d5d0 (diff)
Added by Ermal Luçi about 4 years ago

Fixes #4040 for pppoe use static route with -iface option to help when more than one pppoe has the same gateway. Also kill states when reloading apinger to catch up with new route

History

#1 Updated by Chris Buechler about 4 years ago

  • Assignee changed from Chris Buechler to Ermal Luçi

#2 Updated by Ermal Luçi about 4 years ago

  • Status changed from Confirmed to Feedback

#3 Updated by Ermal Luçi about 4 years ago

  • % Done changed from 0 to 100

#4 Updated by Chris Buechler about 4 years ago

  • Status changed from Feedback to Resolved
  • Affected Version set to All

fixed

Also available in: Atom PDF