Project

General

Profile

Actions

Bug #4333

closed

Shaper wizard retains and uses incorrect info when supplying a different count of interfaces on future runs

Added by Jim Pingle almost 10 years ago. Updated almost 10 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
-
Category:
Traffic Shaper (ALTQ)
Target version:
Start date:
01/28/2015
Due date:
% Done:

100%

Estimated time:
Plus Target Version:
Release Notes:
Affected Version:
2.2
Affected Architecture:
All

Description

If you run through the shaper wizard with, for example, two WANs, then some sections like VoIP get a set of <conn0upload> and <conn1upload> and related tags. If a future run is made with only a single WAN, the <conn1*> tags are removed from the <step2> section but not from <step3> and they are still considered for calculating bandwidth percentages, which leads to an input validation problem that is impossible to clear in the GUI without removing the old <ezshaper> config.

Actions #1

Updated by Ermal Luçi almost 10 years ago

  • Status changed from New to Feedback
Actions #2

Updated by Ermal Luçi almost 10 years ago

  • % Done changed from 0 to 100
Actions #3

Updated by Ermal Luçi almost 10 years ago

Actions #4

Updated by Chris Buechler almost 10 years ago

  • Status changed from Feedback to Resolved

fixed

Actions

Also available in: Atom PDF