Actions
Bug #1001
closedCaptive portal session reuse invalid when MAC changes
Status:
Resolved
Priority:
Low
Assignee:
-
Category:
Captive Portal
Target version:
-
Start date:
11/08/2010
Due date:
% Done:
0%
Estimated time:
Plus Target Version:
Release Notes:
Affected Version:
All
Affected Architecture:
Description
Whenever the CP session timeout is longer than the DHCP lease length, and a different device gets assigned an IP, a new user's login will be detected as "CONCURRENT LOGIN - REUSING OLD SESSION", but it's actually not - the session doesn't work because the MAC isn't checked to ensure it really is a concurrent login.
This is rarely an issue as CP session timeouts are rarely, and should never, be longer than the DHCP lease length in environments with frequently changing devices. Hence not targeting 2.0.
Updated by Chris Buechler over 13 years ago
- Status changed from New to Resolved
this is addressed in #2082
Actions