Project

General

Profile

Bug #5962

IPsec Phase 2 edit page: Remote Network subnet bits field doesn't enable/disable correctly

Added by Renato Botelho over 3 years ago. Updated over 3 years ago.

Status:
Resolved
Priority:
Normal
Category:
Web Interface
Target version:
Start date:
03/08/2016
Due date:
% Done:

100%

Estimated time:
Affected Version:
2.3
Affected Architecture:

Description

I didn't check other similar fields in the same page, like Local Network or NAT/BINAT Translation, but they may have same issue.

When Remote Network field is changed from Address to Network or vice-versa the subnet bits field is not changing accordingly.

Associated revisions

History

#1 Updated by Steve Beaver over 3 years ago

This issue appears to be confined to Chrome. Investigating now.

#2 Updated by Steve Beaver over 3 years ago

  • Status changed from New to Feedback
  • Assignee changed from Steve Beaver to Renato Botelho
  • % Done changed from 0 to 100

Changed selector jQuery from "click" to"change". This seems to make Chrome happy, and does not affect other browsers.

#3 Updated by Renato Botelho over 3 years ago

  • Status changed from Feedback to Resolved

Works, thanks

Also available in: Atom PDF