Bug #12189

closed

IPsec status shows connect buttons while tunnel is connecting

Added by Jim Pingle over 2 years ago. Updated over 2 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Category:
IPsec
Target version:
Start date:
Due date:
% Done:

100%

Estimated time:
Plus Target Version:
22.01
Release Notes:
Default
Affected Version:
Affected Architecture:

Description

When a tunnel is in the "Connecting" state, the IPsec status page at status_ipsec.php shows two connect buttons, when it should show a single disconnect button. Both connect buttons say "Connect P1 and P2s".

Since it's already trying to connect, nudging it to connect again would be potentially problematic, whereas disconnecting will terminate the connection attempt which is more logical.

Check the widget to see if it happens there as well.

Actions #1

Updated by Jim Pingle over 2 years ago

Widget showed a disconnect button already. It showed P1 as connected, however, but if that's not expected that is going to need a separate Redmine since it's a more involved fix.

Actions #2

Updated by Jim Pingle over 2 years ago

  • Status changed from New to Feedback
  • % Done changed from 0 to 100
Actions #3

Updated by Jim Pingle over 2 years ago

  • Status changed from Feedback to Resolved

Working as expected now.

Actions #4

Updated by Jim Pingle over 2 years ago

  • Plus Target Version changed from 21.09 to 22.01
Actions