openNew CoDel limiters are no longer created with any default values
Status:
Incomplete
Priority:
Normal
Assignee:
-
Category:
Traffic Shaper (Limiters)
Target version:
-
Start date:
Due date:
% Done:
0%
Estimated time:
Release Notes:
Default
Affected Plus Version:
24.11
Affected Architecture:
All
Description
When creating new limiters as per the documentation, the parameters are no longer set to default values as was done in previous versions of pfSense. target and interval are both 0
, and quantum , limit , and flows are blank. The text boxes are empty and don't contain any greyed-out text, indicating that no default value is being used. Previously, I believe the default values for CoDel limiters were 5, 100, 1500, 10240, and 1024 respectively.
I am seeing this issue on multiple devices running 24.03 and 24.11. Something might have changed starting with 23.09/23.09.1, as I recall finding several firewalls with existing limiters that showed 0
for interval after being upgraded to 23.09/23.09.1.