Bug #3134
closed
Apinger is not updating monitor IP until it is manually restarted
Added by Jim Pingle over 11 years ago.
Updated about 11 years ago.
Description
After the latest apinger changes, If you edit a gateway and change the monitor IP, a save/apply is not changing the monitor IP as used by apinger, until the process is stopped and restarted.
Jim P wrote:
After the latest apinger changes, If you edit a gateway and change the monitor IP, a save/apply is not changing the monitor IP as used by apinger, until the process is stopped and restarted.
Confirming, after updating today to the 07-08-2013 snapshot, the aping service was down. I had to manually activate it.
Strangely, I've a fail-over (which require a gateway ping to be considered as up) that was been ping correctly even if aping was down ?!
WAN was marked as gathering data
Opt1 was marked as online (with ping)
I've also the feeling that if the connexion switch to the Opt1 (fail-over due to WAN offline), even if WAN come back alive, the connexion will never switch again to WAN unless Opt1 is put offline and bring back online manually.
WAN tier 1, Opt1 tier 2.
- Status changed from New to Feedback
Should be solved in later snapshots.
- Status changed from Feedback to Resolved
- % Done changed from 0 to 100
I still have got a similar behavior with the version "2.1-RELEASE (i386) built on Wed Sep 11 18:16:44 EDT 2013 FreeBSD 8.3-RELEASE-p11"
Configuration:
Gateways:
WAN1
WAN2
WAN3
Gateway Group:
WAN1 > Tier 2
WAN2 > Tier 3
WAN3 > Tier 1
In case WAN3 goes down by unplugging the cable or a reboot of the endpoint of WAN3, all traffic is getting routed to WAN1, which is the next-highest fallback gateway. However, when WAN3 comes online again, all traffic is still being routed to WAN1 and not to WAN3. It`s not only a `broken states`-problem, as a traceroute also shows the same behavior for new / unestablished connections.