Bug #4040

closed

gateway monitoring issues with multiple PPPoE with same gateway

Added by Chris Buechler almost 10 years ago. Updated almost 10 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Ermal Luçi
Category:
Gateway Monitoring
Target version:
Start date:
11/24/2014
Due date:
% Done:

100%

Estimated time:
Plus Target Version:
Release Notes:
Affected Version:
All
Affected Architecture:

Description

With multiple PPPoE connections with the same gateway, the static route for the monitor IP can end up on the wrong interface, which ends up marking the affected gateway as down.

potentially a secondary issue here in that the ICMP state for the monitor IP can cause breakage, such as if the route to a destination changes after the state exists.