Actions
Bug #4735
closedSerial console doesn't work anymore after config restore on RCC-VE systems
Status:
Duplicate
Priority:
High
Assignee:
-
Category:
Backup / Restore
Target version:
-
Start date:
05/28/2015
Due date:
% Done:
0%
Estimated time:
Plus Target Version:
Release Notes:
Affected Version:
Affected Architecture:
Description
Hi,
I installed pfsense from the NETGATE ADI RCC-VE memstick image onto a RCC-VE 2440. Everything worked perfectly but as soon as I restored a config file, I lost the console after the reboot.
It looks like restoring the console strips the comconsole_port="0x2F8" from /boot/loader.conf. That sets back the console port as uart0 instead of uart1.
I don't know if it does the same thing for any restore. I took my .xml file from a PFSense 2.2.2 router (same version) but with different NIC and nanobsd system type. I just replaced the interface names prior to restore so it matches the ones on the new physical router.
Actions