Project

General

Profile

Actions

Bug #5312

closed

system_advanced_admin.php - Serial speed drop-down is saving incorrect values

Added by Jim Pingle about 9 years ago. Updated about 9 years ago.

Status:
Resolved
Priority:
High
Assignee:
Target version:
Start date:
10/16/2015
Due date:
% Done:

0%

Estimated time:

Description

The serial speed drop down should be using the numerical serial speed for both the value and the label, and it's currently using an index for the value which is incorrect and results in boot problems with the serial console enabled.

Actions #1

Updated by Anonymous about 9 years ago

  • Status changed from Confirmed to Feedback
  • Assignee changed from Anonymous to Jim Pingle

Corrected select array type

Actions #2

Updated by Jim Pingle about 9 years ago

  • Status changed from Feedback to Resolved

Tested, works fine now, thanks!

Actions

Also available in: Atom PDF