Project

General

Profile

Actions

Bug #1351

closed

Mobile IPsec no traffic pass trough after 2nd connect after 5 minutes

Added by ronald meulendijks about 13 years ago. Updated almost 10 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
-
Category:
IPsec
Target version:
-
Start date:
03/14/2011
Due date:
% Done:

0%

Estimated time:
Plus Target Version:
Release Notes:
Affected Version:
2.0
Affected Architecture:

Description

When a mobile tunnel is connected for the first time after configuration in pfsense 2.0RC1+shrewsoft client , all traffic is passed trough the tunnel and all is working o.k.
But when the tunnel is disconnected and after waiting for 10 minutes, the tunnel can be connected again but no traffic is passing trough anymore. This situation stays till racoon service is restarted.
then the whole story repeats.


Files

Logs_when_wrong.txt (6.08 KB) Logs_when_wrong.txt ronald meulendijks, 03/15/2011 02:23 PM
TEST_SITUATION.docx (150 KB) TEST_SITUATION.docx Shrewsoft Tracing ronald meulendijks, 04/05/2011 05:28 AM
Actions

Also available in: Atom PDF