Description

When a mobile tunnel is connected for the first time after configuration in pfsense 2.0RC1+shrewsoft client , all traffic is passed trough the tunnel and all is working o.k.
But when the tunnel is disconnected and after waiting for 10 minutes, the tunnel can be connected again but no traffic is passing trough anymore. This situation stays till racoon service is restarted.
then the whole story repeats.