apinger at times fails to touch filter_dirty

Added by Chris Buechler over 14 years ago. Updated over 14 years ago.

Status:
Resolved
Priority:
High
Assignee:
-
Category:
Multi-WAN
Target version:
Start date:
04/22/2010
Due date:
% Done:

100%

Estimated time:
Plus Target Version:
Release Notes:
Affected Version:
2.0
Affected Architecture:

Description

apinger at times fails to touch filter_dirty because it appears something messes with the perms on /tmp

Apr 22 09:45:46    apinger: command (/usr/bin/touch /tmp/filter_dirty) exited with status: 1
Apr 22 09:45:46    apinger: Error while starting command.
Actions #1

Updated by Perry Mason over 14 years ago

Don't know how related it is (with the work around), but in a multi wan setup with failover groups.
If wan fails apinger set it offline and online when it recover
if wan2 fails apinger set it offline and keeps it offline when it should recover.
I then kill apinger and start apinger and wan2 goes online.

Actions #2

Updated by Ermal Luçi over 14 years ago

  • Status changed from New to Feedback

This seem to work ok with Chris workaround.

Perry Mason,

try latest snapshots it should be ok.

Actions #3

Updated by Perry Mason over 14 years ago

No change for me on a day old snapshot. Had a longer fallout on wan2.
After the connection came back I could traceroute to the monitor ip but wan2 was still offline.

Actions #4

Updated by Ermal Luçi over 14 years ago

  • % Done changed from 0 to 100
Actions #5

Updated by Ermal Luçi over 14 years ago

Actions #6

Updated by Ermal Luçi over 14 years ago

Actions #7

Updated by Ermal Luçi over 14 years ago

Perry,

try latest snapshots i have identified the issue should work correctly now.

Actions #8

Updated by Perry Mason over 14 years ago

On a jun 9 snapshot the issue still shows.

Actions #9

Updated by Chris Buechler over 14 years ago

  • Status changed from Feedback to Resolved

this particular issue is resolved