Bug #12468

closed

Stopping IPsec daemon on the Status / Services page lead to log files flooding if pcscd daemon is enabled

Added by Viktor Gurov about 3 years ago. Updated over 2 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Viktor Gurov
Category:
IPsec
Target version:
-
Start date:
Due date:
% Done:

0%

Estimated time:
Plus Target Version:
Release Notes:
Default
Affected Version:
2.5.2
Affected Architecture:

Description

- PC/SC daemon must be stopped before strongswan, otherwise it will flood log
- There is no needs in PC/SC service entry on the Status / Services page - it must be restarted in sync with strongswan daemon


Related issues

Related to Todo #11933: PC/SC Smart Card Daemon ``pcscd`` running on all devices at all times, should be optionalResolvedViktor Gurov05/17/2021