Description

AHCI* disks (/dev/ada#) are not detected in the Diagnostics > SMART status page.

According to diag_smart.php line 280, only ad# or da# devices are retrieved; a small change to include ada# will suffice?


Files

smart_status.png (21.8 KB) smart_status.png Smart status screen Josh G, 08/29/2013 09:41 PM
smart_output.png (41.7 KB) smart_output.png Smart output from ada0 Josh G, 08/29/2013 09:41 PM
Actions #1

Updated by Jim Pingle over 11 years ago

  • Status changed from New to Feedback
  • % Done changed from 0 to 100
Actions #2

Updated by Jim Pingle over 11 years ago

Actions #3

Updated by Josh G about 11 years ago

I have a solid state disk in an Atom D525 that I switched over to use AHCI. I now can see ada0 in the SMART status page. I can view each info type, and running a short offline test worked as expected.

Tested in 2.1-RC1, August 26, 2013 build

Actions #4

Updated by Renato Botelho about 11 years ago

  • Status changed from Feedback to Resolved
Actions