Project

General

Profile

Actions

Bug #4009

closed

Selecting "Embedded" during install does not activate the serial console in a persistent way on amd64

Added by Jim Pingle over 9 years ago. Updated over 9 years ago.

Status:
Resolved
Priority:
High
Assignee:
-
Category:
Console Menu
Target version:
Start date:
11/14/2014
Due date:
% Done:

0%

Estimated time:
Plus Target Version:
Release Notes:
Affected Version:
2.2
Affected Architecture:
amd64

Description

Selecting "Embedded" during install does not activate the serial console in a persistent way on amd64 now that there is no "embedded" kernel there.
If a config.xml is restored that does not include the tags to enable the serial port, the user is left with a broken console.

Easy to reproduce on APU:
  • Install to mSATA in an APU, choose Embedded
  • After install, once it boots, download a config backup
  • Remove "<enableserial/>" from the config backup
  • Restore the backup and wait for it to reboot
  • The unit will boot, but the console never produces a menu at the end of the boot process
  • "Bootup complete" is displayed but no menu

There is some code to force the serial console on ( enableserial_force ) but it may need some adjustment to work in this scenario.

Actions