Description

If you use the webGUI to reset to factory defaults, then while the
existing system is shutting down you navigate off to the dashboard, the
initial setup wizard will start. The trigger_initial_wizard flag file is
deleted, and so after the reboot the initial setup wizard will not be
triggered.

Actions #2

Updated by Renato Botelho almost 9 years ago

  • Status changed from New to Feedback
  • % Done changed from 0 to 100

Merged. Thanks!

Actions #3

Updated by Chris Buechler almost 9 years ago

  • Status changed from Feedback to Resolved

fixed