Project

General

Profile

Actions

Bug #5666

closed

Reset to Factory Defaults initial wizard trigger

Added by Phillip Davis over 8 years ago. Updated about 8 years ago.

Status:
Resolved
Priority:
Low
Assignee:
Category:
Web Interface
Target version:
Start date:
12/21/2015
Due date:
% Done:

100%

Estimated time:
Plus Target Version:
Release Notes:
Affected Version:
All
Affected Architecture:

Description

If you use the webGUI to reset to factory defaults, then while the
existing system is shutting down you navigate off to the dashboard, the
initial setup wizard will start. The trigger_initial_wizard flag file is
deleted, and so after the reboot the initial setup wizard will not be
triggered.

Actions #2

Updated by Renato Botelho over 8 years ago

  • Status changed from New to Feedback
  • % Done changed from 0 to 100

Merged. Thanks!

Actions #3

Updated by Chris Buechler about 8 years ago

  • Status changed from Feedback to Resolved

fixed

Actions

Also available in: Atom PDF