Project

General

Profile

Actions

Regression #14269

closed

1100/2100: switch ports not enabled for auto-mdi-x

Added by aleksei prokofiev about 1 year ago. Updated about 1 year ago.

Status:
Duplicate
Priority:
High
Assignee:
Category:
Hardware / Drivers
Target version:
Start date:
Due date:
% Done:

0%

Estimated time:
Release Notes:
Default
Affected Plus Version:
23.01
Affected Architecture:
SG-1100, SG-2100

Description

In 23.01 the 1100 switch ports do not support auto-MDI/X. The customer try to connect 1100 with 2100 and no success, to fix it needs cross-over cable or switch in the middle.
I tested the 1100 connected directly to the 3100 and it works fine without a crossover cable. Physical loop between interfaces on 1100 shows no carrier, looks like the affected device is 1100, I don't have 2100 to check on it.


Related issues

Related to Regression #13993: Switch ports on 7100/1100/2100 do not have Auto MDI-X support enabledResolvedLuiz Souza

Actions
Actions #1

Updated by Peter Poulos about 1 year ago

aleksei prokofiev wrote:

In 23.01 the 1100 switch ports do not support auto-MDI/X. The customer try to connect 1100 with 2100 and no success, to fix it needs cross-over cable or switch in the middle.
I tested the 1100 connected directly to the 3100 and it works fine without a crossover cable. Physical loop between interfaces on 1100 shows no carrier, looks like the affected device is 1100, I don't have 2100 to check on it.

Hi Alex, i have tested a loop back on the 2100, ports dont light up, 2100 is also AFFECTED. hope this helps :)

Actions #2

Updated by Jim Pingle about 1 year ago

  • Tracker changed from Bug to Regression
  • Subject changed from 1100: switch ports not enabled for auto-mdi-x to 1100/2100: switch ports not enabled for auto-mdi-x
  • Assignee set to Luiz Souza
  • Priority changed from Normal to High
  • Target version set to 23.05
Actions #3

Updated by Jim Pingle about 1 year ago

  • Related to Regression #13993: Switch ports on 7100/1100/2100 do not have Auto MDI-X support enabled added
Actions #4

Updated by Steve Wheeler about 1 year ago

  • Status changed from New to Feedback
  • Affected Architecture SG-2100 added

The same fix that applied to the 7100 is already in 23.05 snapshots. The switch ports link MDI and MDIX there as expected.

Tested:

23.05-DEVELOPMENT (arm64)
built on Mon Apr 10 06:05:58 UTC 2023
FreeBSD 14.0-CURRENT

Actions #5

Updated by Jim Pingle about 1 year ago

  • Status changed from Feedback to Duplicate

Fix appears to be in and working for me as well. I get a link between the LAN and OPT ports on an 1100 running a 23.05 snapshot.

Given that the same fix applies to all of these, this should probably be marked a duplicate instead of a distinct issue.

Actions

Also available in: Atom PDF