Regression #14269

closed

1100/2100: switch ports not enabled for auto-mdi-x

Added by aleksei prokofiev about 1 year ago. Updated about 1 year ago.

Status:
Duplicate
Priority:
High
Assignee:
Category:
Hardware / Drivers
Target version:
Start date:
Due date:
% Done:

0%

Estimated time:
Release Notes:
Default
Affected Plus Version:
23.01
Affected Architecture:
SG-1100, SG-2100

Description

In 23.01 the 1100 switch ports do not support auto-MDI/X. The customer try to connect 1100 with 2100 and no success, to fix it needs cross-over cable or switch in the middle.
I tested the 1100 connected directly to the 3100 and it works fine without a crossover cable. Physical loop between interfaces on 1100 shows no carrier, looks like the affected device is 1100, I don't have 2100 to check on it.


Related issues

Related to Regression #13993: Switch ports on 7100/1100/2100 do not have Auto MDI-X support enabledResolvedLuiz Souza